LP Steam Line Gland Packing

An LP steam line had a leaking gland.

Posted byohcreativeApril 15, 2025May 7, 2025Posted inClamp Leak Repair

2 x 10 Inch Cooling Water Lines

The 2 x 10” lines had suffered from external corrosion

Posted byohcreativeApril 15, 2025June 17, 2025Posted inPipe integrity, Repairs to Tees, elbows and flanges

2 Inch Valve Restraint

The 2 inch valve had failing machine hex nuts

Posted byohcreativeApril 15, 2025May 16, 2025Posted inClamp Leak Repair

2 Inch to 8 Inch LP Steam

The 2-inch line to 8-inch line had suffered from a leak

Posted byohcreativeApril 15, 2025May 16, 2025Posted inClamp Leak Repair

2 Inch Boiler Water Feed Line

The 2-inch line had suffered from a leak

Posted byohcreativeApril 15, 2025May 16, 2025Posted inClamp Leak Repair

Leaking 6 Inch Sea Water Valve

The 6” valve was suffering from severe internal salt water erosion

Posted byohcreativeApril 13, 2025June 17, 2025Posted inLeak Repair, Repairs to Tees, elbows and flanges

24″ LEAKING BURIED CRUDE OIL LINE

The 24” line buried 10 metres below the ground, had suffered from external corrosion which led to a through wall defect.

Posted byohcreativeFebruary 27, 2025Posted inLeak Repair, Pipe integrity

3 x 24 Inch Water Lines

The 3 x 24” lines had suffered from excessive external corrosion at the bottom of the lines which are exiting the concrete floor.

Posted byohcreativeFebruary 27, 2025June 17, 2025Posted inLeak Repair, Pipe integrity

1090mm heat exchanger expansion joint

The heat exchanger was subjected to thermal cycling that caused a crack to appear at the edge of the expansion joint

Posted byohcreativeFebruary 27, 2025Posted inLeak Repair, Pipe integrity, Repairs to large diameter pipelines

20″ Wet Air Line

The 20” line had suffered from CUI external corrosion on the pipe coming off the vessel.

Posted byohcreativeFebruary 27, 2025February 27, 2025Posted inLeak Repair, Pipe integrity

Posts pagination

Newer posts 1 … 3 4 5 6 7 … 9 Older posts
Linkedin Twitter
  • 0800 121 7777
  • METALYTE PIPEWORKS LTD
    Unit M Riverside Industrial Estate Atherstone Street Fazeley Tamworth Staffordshire B78 3RW
  • COMPANY NUMBER: 08126595
    Registered in the UK

© All rights reserved

legal

  • Privacy Policy
  • Cookies Policy
  • How to Opt Out
  • Terms & Conditions
VIEW OUR ISO9001 CERTIFICATION
VIEW OUR ISO14001 CERTIFICATION
VIEW OUR QUALITY POLICY
Website by OH Creative