MP Case History

16 Inch Heavy Oil Line Repairs

The 16” line had suffered from external corrosion.

NATURE OF DEFECT

The 16” line had suffered from external corrosion. This resulted in wall thinning. The client requires a composite repair to halt the corrosion and bring the line back up

SOLUTION

Metalyte Pipeworks produced a repair method using Herculyte epoxies to infill the defects with a minimum overwrap of 10 layers of Dragon-Q-STD composite system.

REPAIR METHOD

The surface was prepared (excluding the identified defect area) using an MBX machine to gain a surface profile to SSP.SP11 and surface defects within the immediate repair area were repaired using Herculyte epoxies. 500 microns of Dragon resin was applied as a bonding coat to the entire repair area prior to application of the Dragon composite. The repair area was wrapped in 10 layers of Engineered Dragon-Q-STD composite and allowed to cure until a minimum of 74.5 “Shore D” hardness was achieved.

Recent Case Histories